![]() ![]() ARGUS Umweltbiotechnologie GmbH
© 2024 ARGUS Umweltbiotechnologie GmbH
ServicesExploratory drilling and soil sampling Groundwater sampling Soil-vapour sampling using Dräger-Stitz and DESAGA (mobile)Recording of soil description, layer specifications, sampling 2. Groundwater- and Surface water-Sampling • Groundwater Monitoring Well Installation (e.g. 2" Well) • Bailer Sampling of Monitoring Wells • Surfacewater Turbidity test, using Secchi disk • Pump Sampling of Monitoring Wells • Field-Parameter Analysis • Passive-sampler (Ceramic-dosimeter)1. Planning and Implementation of Investigatory Bores and Soil SamplingAccording to objectives: • Slit-Sounding (d=22 mm) • Core-Sounding (d=36-80 mm) • Rotary Drilling (d=80 mm) • Test-Pitting (DIN 4124) • Landfarm-Sampling (LAGA PN 98, DIN 18123) • Organoleptic Assessment • Sediment-Sampling, using Multisampler4. Pumping Tests and Soil-Vapour Extraction Tests • Carrying-Out and Evaluation of Pumping Tests in accordance with DVGW for determination of geo-hydraulic![]() and hydro-chemical Parameters within the scope of Remediation Preliminary Investigations![]() - Organisation, Monitoring, Control und Documentation of Test Procedure ![]() - Installation, Programming und Monitoring of Datenloggers ![]() - Determination of the Range of Groundwater Drawdown![]() - Determination of Contaminant Discharge / Load Calculation![]() - Calculation of Contamination Development • Carrying-Out of Soil-Vapour Extraction Tests in accordance with ITVA Guidelines ![]() - Organisation, Monitoring, Control and Documentation of Test Procedure![]() - Determination of Vapour-Withdrawal Range![]() - Calculation of Contamination Development5. Reporting • Sampling Protocol Compilation • Production of Soil Logs in accordance with DIN 4021, 4022, 4023 and local pedological Cartography • Presentation of the geological, hydrogeological and hydrochemical conditions of the site (GeoDin, Surfer) • Compilation of Site Plans (AutoCAD) • Compilation of Geological Survey • Production of an Evaluation Assessment with regard to various Maximum-Allowable Concentrations ![]() and Guidelines (LAGA, BBodSchV, Berliner Liste etc.) • Contamination Risk Assessment • Appraisal of Remediation MethodsInvestigation of contaminated sites 3. Soil-Vapour- and Room-Air Sampling • Installation of stationary Soil-Vapour Monitoring Wells (1,5"-2") • Implementation of Soil-Vapour Monitoring from Wells (stationary) • Implementation of mobile Soil-Vapour Monitoring (Dräger-Stitz-Sounding) • Ambient-Air Investigation, using Passive-sampler • Additional Sampling-systems:![]() - Soil-Vapour Pump DESAGA with Pressure-compensation and Flowrate Setting![]() - META-Sampling Installation and Landfill Gas Monitor![]() - PID and Multiwarn![]() ![]() ![]() ![]() ![]() |